Monday, 4 January 2016

4:32:00 pm

 

Dear Sir
Drilling through mesh is the option if already it is supported by wire mesh and the wire mesh is to be replaced or additional bolts are to be fixed. In freshly exposed roof we need to dress and support with props and after fixing 3 bolts in a row fix the wire mesh and then proceed once again as before

D.Baidya
DGM Corporate Safety
9491144283
Singareni Colleries Company Limited
( A Govt. Company)

On 2 January 2016 at 17:34, Raj Chakravarty raj.nitrkl@yahoo.com [dgms_mail_list] <dgms_mail_list@yahoogroups.com> wrote:
 

The roof is supported through resin bolts. 




Dear Members,

I want to know the best procedure to install wire mesh in a coal roof having slips. The roof is already supported through roof bolts.

Doesn't opening the existing roof bolts to secure the mesh weaken them ?

Is fresh bolting the only way to secure it ? Coz the drillers say they have problems getting their drill bits through the mesh.




__._,_.___

Posted by: debdulal baidya <debdulal.baidya@gmail.com>
Reply via web post Reply to sender Reply to group Start a New Topic Messages in this topic (4)
_________________________________________________________________
Directorate General of Mines Safety, Ministry of Labour & Employment, Govt. of India   
Websites: http://www.dgms.net and http://www.dgmsindia.in and http://www.dgms.gov.in
--------------------------------------------------------------------------------------------------------
If for any reason you wish to unsubscribe from DGMS Mailing List, send an email to:
dgms_mail_list-unsubscribe@yahoogroups.com

.

__,_._,___

0 comments: