An addition to the previous mail by Mr. Sunil Kumar. Include the head losses at bends as well.

On Mon, Jan 4, 2016 at 5:15 AM, Sunil Kumar Dagliya sunil_kd@hindustancopper.com [dgms_mail_list] <dgms_mail_list@yahoogroups.com> wrote:
 

Calculate the friction head (depends upon internal dia of pipe,material of construction of pipe and discharge quantity per hour) + Static head (i.e. Level difference) = Total head.
 
Again depending upon total head and quantity search the manuals of the pump and find suitable one.

-----dgms_mail_list@yahoogroups.com wrote: -----
To: dgms_mail_list@yahoogroups.com
From: "Partha Sarathi parthadas7933@yahoo.com [dgms_mail_list]"
Sent by: dgms_mail_list@yahoogroups.com
Date: 01/03/2016 11:46AM
Subject: DGMS Mailing List: pump calculation

 

can somebody provide me tips for calculation of pump capacity & head for opencast mine drainage. need a formulae also ?

This message has been scanned by IMSVA
Message is Scanned by Trend Micro - Hindustan Copper Limited
Message is Scanned by Trend Micro - Hindustan Copper Limited  
This message has been scanned by IMSVA


__._,_.___

Posted by: Jevendiran Ramadasu <jevendiran@gmail.com>
Reply via web post Reply to sender Reply to group Start a New Topic Messages in this topic (3)