Monday, 4 January 2016

4:30:00 pm

 

Dear Sir
Our experience is there is no problem in drilling through the mesh with pneumatic or hydraulic roof bolters.

Regards

D.Baidya
DGM Corporate Safety
9491144283
Singareni Colleries Company Limited
( A Govt. Company)

On 2 January 2016 at 17:34, Raj Chakravarty raj.nitrkl@yahoo.com [dgms_mail_list] <dgms_mail_list@yahoogroups.com> wrote:
 

The roof is supported through resin bolts. 




Dear Members,

I want to know the best procedure to install wire mesh in a coal roof having slips. The roof is already supported through roof bolts.

Doesn't opening the existing roof bolts to secure the mesh weaken them ?

Is fresh bolting the only way to secure it ? Coz the drillers say they have problems getting their drill bits through the mesh.